Bloqueo infraclavicular continuo guiado

Bloqueo infraclavicular continuo guiado por ultrasonido para cirugía de mano. Reporte técnico de la posición del brazo para la colocación del catéter perineural
Ultrasound-guided continuous infraclavicular block for hand surgery: Technical report on arm position for perineural catheter insertion
Fuente
Este artículo es originalmente publicado en:
http://www.ncbi.nlm.nih.gov/pubmed/25982603
http://www.elsevier.es/es-revista-cirugia-cirujanos-139-resumen-bloqueo-infraclavicular-continuo-guiado-por-S0009741115000213
De:
Zaragoza-Lemus G1,Hernández-Gasca V2,Espinosa-Gutiérrez A3.
Cir Cir.2015 Jan-Feb;83(1):15-22. doi: 10.1016/j.circir.2015.04.018.
Todos los derechos reservados para:
Copyright © 2015. Published by Masson Doyma México S.A.ResumenAntecedentes
La infusión perineural de anestésico local brinda mejor analgesia postoperatoria que la administración por vía intravenosa de opioides o antiinflamatorios en cirugía del miembro superior. Para colocar un catéter en el plexo braquial, el abordaje adecuado es el infraclavicular debido a que ofrece mayor estabilidad muscular. La abducción del brazo aparentemente coloca al plexo braquial más superficial, y que eleva en sentido cefálico la clavícula.
Objetivo
El objetivo de este trabajo es identificar si la abducción disminuye la distancia pielcordón y facilita el procedimiento de introducción del catéter por ultrasonido, asegurando una analgesia óptima. Esta posición del brazo y su relación con la colocación del catéter no se habían descrito anteriormente.
Material y métodos
Se incluyó a 58 pacientes adultos, sometidos a cirugía de antebrazo y mano, divididos en 2 grupos por colocación de la extremidad en abducción y aducción, se realizó un bloqueo infraclavicular mediante ecografía, colocando la punta del catéter adyacente al cordón posterior. En los pacientes del grupo en aducción con dificultad técnica elevada se permitió cambiar el brazo a abducción. Se registraron el número de punciones y de redirecciones, la facilidad de introducción del catéter y la distancia piel-plexo.
Resultados
La abducción del brazo desplazó cefálicamente la clavícula y la separó del transductor lineal, lo que permitió maniobrar la aguja en su angulación y redirección correcta, la distancia plexo a piel no disminuyó de manera significativa con la posición del brazo.
Conclusiones
La abducción del brazo permite un mejor rastreo en los bloqueos supraclaviculares guiados por ultrasonido y facilita la punción infraclavicular con la introducción del catéter.
AbstractBackground
Continuous perineural infusion of local anaesthetic provides better postoperative analgesia than intravenous administration of opioids or NSAIDs in upper limb surgery. The infraclavicular approach is a good option, due to the muscular stability to catheter; the abduction of the arm apparently makes the brachial plexus more superficial and which elevates the clavicle in the cephalic direction.
Aim
The aim of this study was to identify whether the abduction of the arm decreases the skin-plexus distance, making the perineural insertion of the catheter easier and for a better analgesia. This relationship between the arm and the insertion of catheter has not yet been established.
Material and methods
The study included 58 adult patients, undergoing forearm and hand surgery, initially divided into two groups, adduction and abduction. Ultrasound-guided infraclavicular block was performed, enabling the catheter tip to be positioned adjacent to the posterior cord. The group of patients with high technical difficulties were allowed to reposition the arm abduction. A record was made of the number of punctures, redirects, ease of insertion of the catheter, and skin-plexus distance.
Results
The abduction of the arm moved the clavicle towards the cephalad and separated it from the linear transducer, this allowed to manoeuvre the needle right angle and redirect it. The skin-plexus distance did not decrease significantly with arm position.
Conclusions
Arm abduction allows better scanning, facilitates the infraclavicular puncture, and catheter introduction.
Palabras claveBloqueo infraclavicular, Catéter, Ultrasonido, Cirugía de manoKeywordsCatheter, Infraclavicular block, Ultrasound, Hand surgeryPMID:
25982603
DOI:
10.1016/j.circir.2015.04.018
[PubMed – indexed for MEDLINE]
Free full text
Fuente:clinicademano.com.mx
#Bloqueo infraclavicular#cirugía de mano#ultrasonido http://ow.ly/i/mrNeG http://ow.ly/i/mrNfk http://ow.ly/i/mrNfV

Anuncios

Responder

Introduce tus datos o haz clic en un icono para iniciar sesión:

Logo de WordPress.com

Estás comentando usando tu cuenta de WordPress.com. Cerrar sesión / Cambiar )

Imagen de Twitter

Estás comentando usando tu cuenta de Twitter. Cerrar sesión / Cambiar )

Foto de Facebook

Estás comentando usando tu cuenta de Facebook. Cerrar sesión / Cambiar )

Google+ photo

Estás comentando usando tu cuenta de Google+. Cerrar sesión / Cambiar )

Conectando a %s